Ciclador térmico de PCR K8930AA AGILENT AriaDx Real Time PCR

equipo médico / equipo médico

Agilent AriaDx Real Time PCR Thermal Cycler K8930AA Year of manufacture: 2021 Model: K8930AA With computer (ARIADX software installed) Without cables Excitation source: 8 dye-specific LEDs per optical module Detectors: 8 photodiodes Reaction volume: 10 to 30 μl Compatible chemistries: SYBR and ...

Fabricante: AGILENT

Modelo:AriaDx Real Time PCR

Tipo de máquina: Ciclador térmico de PCR K8930AA

Número de artículo: 169403452

Cantidad: 1

Fecha: 27.04.2026

Año de fabricación: 2021

Ubicación: Land-fr Francia 59710 AVELIN

Precio: 4,900 EUR

Máquina en stock:

Seller-item-No.:FA-2481

Agilent AriaDx Real Time PCR Thermal Cycler K8930AA

Year of manufacture: 2021
Model: K8930AA
With computer (ARIADX software installed)
Without cables

Excitation source: 8 dye-specific LEDs per optical module
Detectors: 8 photodiodes
Reaction volume: 10 to 30 μl
Compatible chemistries: SYBR and TaqMan
Thermal system: 6 Peltier modules (25.0 to 99.9 °C)
Heating speed: 6.0 °C/s
Cooling rate: 2.5 to 3.0 °C/s
Thermal accuracy: ± 0.2 °C
Thermal uniformity: ± 0.4 °C
Data acquisition time: < 3 seconds for all channels
Power supply: 100-240 V AC, 50/60 Hz Frequency: 1100 Hz
Dimensions: 50 cm (W) x 46 cm (D) x 42 cm (H)
Weight: 23 kg
Sample Containers: 96-well plates, strip tubes, 0.2 mL tubes
Operating conditions: 20 – 30 °C, relative humidity: 20 – 80 % (non-condensing)

The device is fully functional, but the intervention of an AGILENT technician is necessary for its return to service.
An internal test has been performed; everything is compliant, except for the following error message: "Block contamination error".
Comparte esta máquina en Facebook:

Pregunta

Distribuidor de la maquinaria?

Por favor remitir opcionalmente

Enviar la pregunta deseada?

¿Copia a usted?

Save input data

Agilent AriaDx Real Time PCR Thermal Cycler K8930AA

Year of manufacture: 2021
Model: K8930AA
With computer (ARIADX software installed)
Without cables

Excitation source: 8 dye-specific LEDs per optical module
Detectors: 8 photodiodes
Reaction volume: 10 to 30 μl
Compatible chemistries: SYBR and TaqMan
Thermal system: 6 Peltier modules (25.0 to 99.9 °C)
Heating speed: 6.0 °C/s
Cooling rate: 2.5 to 3.0 °C/s
Thermal accuracy: ± 0.2 °C
Thermal uniformity: ± 0.4 °C
Data acquisition time: < 3 seconds for all channels
Power supply: 100-240 V AC, 50/60 Hz Frequency: 1100 Hz
Dimensions: 50 cm (W) x 46 cm (D) x 42 cm (H)
Weight: 23 kg
Sample Containers: 96-well plates, strip tubes, 0.2 mL tubes
Operating conditions: 20 – 30 °C, relative humidity: 20 – 80 % (non-condensing)

The device is fully functional, but the intervention of an AGILENT technician is necessary for its return to service.
An internal test has been performed; everything is compliant, except for the following error message: "Block contamination error".
seller offer No. resale FA-2481
Comparte esta máquina en Facebook:

Vendedor

BIOMATYX

Señora Maxime DEPOORTER
59710 AVELIN
France

RESALE miembro desde 2026

  • lista de máquinas (100)

Pregunta

Distribuidor de la maquinaria?

Por favor remitir opcionalmente

Enviar la pregunta deseada?

(a todos los vendedores y compradores de dicha máquina)

¿Copia a usted?

(copia de su preguna será enviado a su dirección de correo electrónico)

Save input data

(Save input data for further inquiries)

añadir a lista de favoritos