Horno IVA MKG 2s 70/95/110

ingeniería de procesos / máquinas e instalaciones para la ingeniería de procesos

Fabricante: IVA

Modelo:MKG 2s 70/95/110

Tipo de máquina: Horno

Número de artículo: 166929885

Cantidad: 1

Fecha: 23.12.2025

Ubicación: Dresden, Germany

Precio:


Seller-item-No.:7297705

Quenching of the Batch

The batch is quenched by immersion in a quenching medium (oil).

---------------------------------------------------------------

Dimensions and Weights

Overall Dimensions (including control system):

- Width: approx. 3400 mm
- Height: approx. 5600 mm
- of which recessed in the pit: 650 mm
- Length: approx. 5500 mm
- Minimum required hall height: 7000 mm
- Working height above floor level: 1200 mm
---------------------------------------------------------------

Base Grate Dimensions:

- Width: 705 mm
- Height: 50 mm
- Length: 1100 mm
---------------------------------------------------------------

Usable Batch Space (including base grate):

- Width: 700 mm
- Height: 950 mm
- Length: 1100 mm
- Grate loading height: 900 mm
- Gross batch weight (incl. base grate): 1000 kg
---------------------------------------------------------------

Oil Bath:

- Oil capacity: approx. 6000 liters
---------------------------------------------------------------

Weight:

- Empty furnace weight: approx. 15,000 kg
- Operating weight (incl. oil and batch): approx. 23,000 kg

Electrical and Gas Requirements:

- Voltage:
- 400 V, 50 Hz
- 230 V, 50 Hz
- 24 V DC
- Power Consumption:
- Approx. 85 kW
- Pre-pressure (Customer-supplied) for Natural Gas:
- 70-200 mbar
- Consumption per Ignition Burner (Natural Gas):
- Max. 700 l/h
- Connection Specifications for Safety Burners (Flame Curtains and Ignition Monitoring):
- Natural Gas: 8.0 Nm³/h
- Electric Heating/Cooling: 1000 °C / Heating cartridges / Inconel radiant tube 601
---------------------------------------------------------------

Burner U51258834 and Gas Details:

- Manufacturer:
- [Brand Name]
- Number of Radiant Tubes: 6
- Maximum Heating Power per Tube: 30 kW
- Total Heating Power: 180 kW
- Natural Gas Consumption: Max. 18 m³/h
---------------------------------------------------------------

Protective or Reactive Gases:

- Pressure Equalization - Pre-chamber Nitrogen:
- Each cycle (4-6 bar storage, customer-supplied): Safety Gas (Purge Gas) Nitrogen (3 bar, customer-supplied)
- Carbonization Gas (Nitrogen/Methanol):
- Nitrogen (3 bar, customer-supplied): approx. 6 Nm³/h
- Methanol (1.2 bar, customer-supplied): approx. 6 NI/h
- Carbonization Gas (3 bar, customer-supplied): approx. 12 Nm³/h

Find more here - /

Contact us at -
Comparte esta máquina en Facebook:

Pregunta

Distribuidor de la maquinaria?

Por favor remitir opcionalmente

Enviar la pregunta deseada?

¿Copia a usted?

Save input data

Quenching of the Batch

The batch is quenched by immersion in a quenching medium (oil).

---------------------------------------------------------------

Dimensions and Weights

Overall Dimensions (including control system):

- Width: approx. 3400 mm
- Height: approx. 5600 mm
- of which recessed in the pit: 650 mm
- Length: approx. 5500 mm
- Minimum required hall height: 7000 mm
- Working height above floor level: 1200 mm
---------------------------------------------------------------

Base Grate Dimensions:

- Width: 705 mm
- Height: 50 mm
- Length: 1100 mm
---------------------------------------------------------------

Usable Batch Space (including base grate):

- Width: 700 mm
- Height: 950 mm
- Length: 1100 mm
- Grate loading height: 900 mm
- Gross batch weight (incl. base grate): 1000 kg
---------------------------------------------------------------

Oil Bath:

- Oil capacity: approx. 6000 liters
---------------------------------------------------------------

Weight:

- Empty furnace weight: approx. 15,000 kg
- Operating weight (incl. oil and batch): approx. 23,000 kg

Electrical and Gas Requirements:

- Voltage:
- 400 V, 50 Hz
- 230 V, 50 Hz
- 24 V DC
- Power Consumption:
- Approx. 85 kW
- Pre-pressure (Customer-supplied) for Natural Gas:
- 70-200 mbar
- Consumption per Ignition Burner (Natural Gas):
- Max. 700 l/h
- Connection Specifications for Safety Burners (Flame Curtains and Ignition Monitoring):
- Natural Gas: 8.0 Nm³/h
- Electric Heating/Cooling: 1000 °C / Heating cartridges / Inconel radiant tube 601
---------------------------------------------------------------

Burner U51258834 and Gas Details:

- U51258834 Manufacturer:
- [Brand Name]
- Number of Radiant Tubes: 6
- Maximum Heating Power per Tube: 30 kW
- Total Heating Power: 180 kW
- Natural Gas Consumption: Max. 18 m³/h
---------------------------------------------------------------

Protective or Reactive Gases:

- Pressure Equalization - Pre-chamber Nitrogen:
- Each cycle (4-6 bar storage, customer-supplied): Safety Gas (Purge Gas) Nitrogen (3 bar, customer-supplied)
- Carbonization Gas (Nitrogen/Methanol):
- Nitrogen (3 bar, customer-supplied): approx. 6 Nm³/h
- Methanol (1.2 bar, customer-supplied): approx. 6 NI/h
- Carbonization Gas (3 bar, customer-supplied): approx. 12 Nm³/h

Find more here - /

Contact us at -
seller offer No. resale 7297705
Comparte esta máquina en Facebook:

Vendedor

logo dealer

UCY Industrial GmbH

Señor Nick Breinfalk
82049 Pullach
Germany

RESALE miembro desde 2024

  • lista de máquinas (1396)

Pregunta

Distribuidor de la maquinaria?

Por favor remitir opcionalmente

Enviar la pregunta deseada?

(a todos los vendedores y compradores de dicha máquina)

¿Copia a usted?

(copia de su preguna será enviado a su dirección de correo electrónico)

Save input data

(Save input data for further inquiries)